Human C-C Chemokine Receptor Type 8 (CCR8) ELISA Kit

Human C-C Chemokine Receptor Type 8 (CCR8) ELISA Kit

Product Overview

Product Name:
Human C-C Chemokine Receptor Type 8 (CCR8) ELISA Kit
Catalog No:
OTH06133
Sensitivity:
0.1 ng/mL
Species Reactivity:
Human
Assay Range:
0.156-10 ng/mL
Application:
Quantitative
Sample Type:
Tissue homogenates, cell lysates and other biological fluids

Product Properties

Storage:
Short-term storage at 4℃, some reagents should be kept at -20℃ when not in use for a long time.
Duration:
3.5 h
Detection Method:
Colorimetric
Assay Type:
Sandwich
Specificity:
This ELISA kit has excellent specificity for the detection of C-C Chemokine Receptor Type 8.
Format:
96-Well Plate
Size:
96T
Shipping Condition:
Ice packs
Standard Form:
Lyophilized
Cross Activity:
It has been verified that this product has high specificity and sensitivity to C-C Chemokine Receptor Type 8, and no significant cross-reactivity or interference with analogues was observed.
Assay Procedure Summary:
1. Prepare the reagents, standards, and samples needed for testing; 2. Aliquot 100 µl of diluted standard into the standard wells; 3. Aliquot 100 µl of standard diluent buffer into control (zero) well; 4. Add 100 µL/well sample to the microtiter plate, incubate 90 min at 37°C; 5. Then add 100 µL of the prepared detection solution A, incubate 1 h at 37°C; 6. After washing the plate 3 times, add 100 µL of the prepared detection solution B and incubate 30 min at 37°C; 7. After washing the plate 5 times, add 90 µL of substrate solution and incubate 10-20 min at 37°C; 8. Terminated by the addition of 50 µL stop solution, the absorbance was read at 450 nm by a microplate reader.
ELISA Kit Components:
Pre-coated 96-Well Microplate
Standard
Solution A
Solution B
Wash Buffer
Detection Solution A
Detection Solution B
Standard Diluent Buffer
TMB Substrate
Stop Solution
Precautions before Use:
The kits of this ELISA kit are not assembled, please assemble it before use.
Stop Solution:
The stop solution of this kit contains acid. Please pay attention to safe use and avoid direct contact.
Notice:
In order to reduce the influence of various variables on the experimental results during the experiment, you must strictly control the experimental conditions, and the entire experimental operation process should be completed by the same person.

Target Info

Target:
C-C Chemokine Receptor Type 8
Target Synonyms:
CCR8
KEGG:
hsa:1237
String:
9606.ENSP00000326432
UniProt Entry Name:
CCR8_HUMAN
UniProt Primary AC:
P51685
UniProt Secondary AC:
B2RC64, Q3KNQ8, Q3KNR3, Q9BYX5
For Research Use Only. Not for Clinical Use.